Specifications
Corrected & Current Anomalies
SPECTRUM Software Release Notes Page 187
SynOptics 5000 Hubs
Corrected Anomalies:
1 In the Configuration view for the HubSyn5xxx model, Chassis Contact
and Chassis Location MIB objects are read-write on the device and
the device can now be set with SNMP.The SM-SYN1003 management
module now supports the 5005 chassis.
Known Anomalies:
Problem 1: SynOptics only counts Good Frames when monitoring
Ethernet traffic. As the number of frames with errors goes up, the number
of Good Frames goes down, and this directly affects the Load value in the
Port, Segment, Cluster, and Attachment Performance views.
Solution: This is an agent problem. Users must evaluate the %Errors in
the Performance views and know that when the %Errors goes up, the Load
displayed does not reflect the actual load on the Ethernet segment.
SPECTRUM
Part Name
Device
Firmware
Version
MM
Version
SM-SYN1003 53xx Enet
55xx TR
59xx FDDI
1.5.1
1.5.1
2.2.6
6.0 Rev 0
SM-SYN1007 SynOptics
D5xxx
1.5.0 6.0 Rev 0