SmartSwitch FDDI (9F310-02, 9F426-02, 9F426-03)
Known Anomalies:
Problem 1: In the Interface Device view of a 9F426-02, three possible
interfaces can appear. One is the INB interface and the others are FDDI
interfaces. The FDDI interfaces can be Front Panel 1 and Front Panel 2,
Front Panel 1 and FNB, or Front Panel 2 and FNB. However, if one panel
is the FNB, the view does not identify which one.
Solution: You can find the desired internal connections information by
opening the Utilities > Applications > FNB Configuration view and find the
desired FDDI information via the FddiMACApp icon in the Applications
view.
SPECTRUM
Part Name
Devices
Firmware
Version
MM
Version
SM-CSI1035 SmartSwitch 9F426_02
SmartSwitch 9F426_03
SmartSwitch 9F310_02
1.06.09 6.0 Rev 0