Specifications

Corrected & Current Anomalies
SPECTRUM Software Release Notes Page 180
SmartSwitch ATM - Zeitnet Switch (2500, 6500,
6A000, 9A100)
Known Anomalies:
Problem 1: In the Device Topology view for the ZX_250 model type, the
Port Load Status field is blank.
Solution: This is a firmware problem.
Problem 2: PVC links, cross connections, paths and channels cannot be
created on a on a Zeitnet device. This happens with the 9A100 or
SmartSwitch 6500 with the Write community name and the trusted NMS
address set correctly.
Solution: This problem will be addressed in a future release.
Problem 3: The Zeitnet System Information view for the SmartSwitch
6500 displays red-boxed fields.
Solution: This is a firmware problem.
Problem 4: For the Zeitnet devices, some interfaces within the Interface
Device and Device Topology views show incorrect IP or MAC addresses.
Solution: This is a firmware problem.
Problem 5: The ZX_250 Switch Application Port view shows the Number
SPECTRUM
Part Name
Switches
Firmware
Version
MM
Version
SM-CSI1085 SmartSwitch 2500 (standalone
ATM; the former Zeitnet ZX-250)
SmartSwitch 6A000 (ATM module)
SmartSwitch 9A100
(ATM module)
SmartSwitch 6500 (ATM
backbone)
2.04.09 6.0 Rev 0