Specifications
Corrected & Current Anomalies
SPECTRUM Software Release Notes Page 177
entries within the Static Bridging application’s Static Bridging Table. This
only happens with some SmartSwitch 9000 modules; for example; the
9E133-36, 9E138-36, 9E423-24, and 9F310-02 SmartSwitch models
display the following:
Update failed for the following attributes:
Attribute 0x1194c - Attribute doesnÕt exist on
device,0x200000a
Solution: In order for the Static Bridging Table to work correctly, a
“MacAddr.receiveport” entry must be provided. Then, click the Create
Static Database Entry, confirm the”MacAddr.receive” value’s existence,
click Close, and click Save again. This saves the MAC address as a Static
Database Entry, and the error message will not appear.
Problem 5: For the 9T125_08 and 9T122_24, the CsTRing1App’s
Cabletron Token Ring Ring Configuration View shows ?? within the Beacon
State field.
Solution: This is a firmware problem.
Problem 6: After modeling a 9E312_12 device, the port interfaces in
Device Topology and Device views are not appearing. Twelve interface ports
should appear in the views. Also, the Model Information view displays the
model state value as "Error."
Solution: This firmware problem will be addressed in a future release.
Problem 7: You may have difficulty creating (and removing) PVCs and
PVPs from SmartCell, 9A656_04, and 9A686_04 devices.
Solution: Use the Virtual Channel views available for your device to
create PVCs and the Virtual Path views to create PVPs. The creation
procedures are the same. Basically, creating a PVC involves defining
individual links (VPI/VCI) on each of two ports and then cross connecting
the ports. You use a virtual channel link view to define the links on each
port and then use a cross connect view to cross connect the ports. Check
the following before you begin: you must have write privileges for the
device; the traffic parameters for the ports must be set properly; and the