Specifications

Corrected & Current Anomalies
SPECTRUM Software Release Notes Page 176
Common Anomalies - SmartSwitch 9000/9500
The following affect two or more management modules and the associated
devices.
Known Anomalies:
Problem 1: Currently, you can create SmartSwitch 9000 models in
Location or Organization views, even though a Contains relation cannot be
established with the SmartSwitch chassis model, and the models do not
show up in the Device view of the SmartSwitch.
Solution: Do not create any SmartSwitch 9000 models in the Location or
Organization views; instead create the model in the Topology view and then
copy the device icon from the Universe Topology view into the Location
view. The SmartSwitch chassis model has a Container view which contains
Location view icons for all modeled SmartSwitch modules. This ensures
that the proper relationship between the models exists.
Problem 2: 9E42x-x and 9H42x-xx device Transparent Bridging Port
tables show no MIB-II Interface statistic for INB interfaces for Port In
Frames, Port Out Frames, and Port In Discards.
Solution: This will be addressed in a future release.
Problem 3: When modeling a 9A6x6 as a standalone, the Chassis Device
view incorrectly displays the backplane interfaces.
Solution: This is a firmware problem; upgrade to 3.00.04 or a later
firmware version.
Problem 4: Error messages may appear when you attempt to save created
SM-CSI1098 9E5xx-xx
9G5xx-xx
9H5xx-xx
1.02.09 6.0 Rev 0
SPECTRUM
Part Name
Devices Firmware
Version
MM
Version