Specifications

Corrected & Current Anomalies
SPECTRUM Software Release Notes Page 137
Cisco Catalyst
Known Anomalies:
Problem 1: The HubCat5000 and HubCat5500 Interface Translation table
shows only Interface Index 1.
Solution: This is a firmware problem; the management module functions
as designed.
Problem 2: Modeling the HubCat5000, opening the Interface Device or
Device Topology views, and exiting after the ports configure, causes
multiple lines of the following message to appear:
CsDIEnumText: No match for Enumerated Value 268836429
Solution: This is a firmware problem; the management module functions
as designed. The device is sending incorrect interface information to
SPECTRUM.
Problem 3: For SwCat1200 models, clicking the CATStackApp’s
Configuration view Clear MAC or Clear Ports button causes a
SpectroGRAPH error message to display.
Solution: Use the read/write Community Name when modeling the
device. Then, each time you click either button, it clears and sets all MAC
and port counter attribute values to “0.”