SmartSwitch 9000 9F206-02 Local Management Appendix 9031682-01
Appendix 9F206-02 Module Specific Information Introduction This appendix contains local management information that is speciÞc to the 9F206-02 FDDI Repeater Module. The 9F206-02 FDDI Repeater Module physically attaches to the FNB-1 and the FNB-2 on the SmartSwitch 9000Õs FNB backplane. By default, the module inserts into four rings (the primary and secondary rings of the FNB-1 and the FNB-2). The 9F206-02 ConÞguration Screen allows you to customize this conÞguration to your particular needs.
9F206-02 Module Specific Information Inserted FDDI-1 Front Panel Connections Backplane A B FNB-1 Inserted A B FDDI-2 FNB-2 Bypassed FDDI-1 Front Panel Connections FDDI-2 Backplane A B FNB-1 Inserted A B FNB-2 Figure 1. Front Panel Connections “Inserted” and “Bypassed” The 9F206-02 ConÞguration Screen (Figure 2), displays the current conÞguration of the moduleÕs front panel connections in relation to the FNB rings on the SmartSwitch 9000 backplane, and allows you to change the conÞguration.
9F206-02 Module Specific Information The 9F206-02 Configuration Screen The 9F206-02 ConÞguration Screen (Figure 2), displays conÞguration and status information about the 9F206-02 Module. SMARTSWITCH 9000 LOCAL MANAGEMENT 9F206-02 CONFIGURATION Module Name: Slot Number: 9F206-02 12 Firmware Revision: BOOTPROM Revision: 02.00.01 01.01.
9F206-02 Module Specific Information 9F206-02 Configuration Screen Fields The following information brießy explains each 9F206-02 ConÞguration Screen Þeld. FNB-1 Status (Toggle) Allows you to control whether or not the moduleÕs FDDI-1 front panel ports will connect (insert) to the backplaneÕs FNB-1 rings (see Figure 1). ¥ When set to Inserted, the moduleÕs FDDI-1 (A and B) ports insert directly into the backplaneÕs FNB-1 primary and secondary rings.
9F206-02 Module Specific Information (DAS-1) Port A Status Displays the status (Link or No-Link) and the connection type (A-A, A-B, or A-M) of the moduleÕs FDDI-1 front panel A port. The value ÒLinkÓ indicates that an operating workstation is connected to the moduleÕs FDDI-1 front panel A port. (DAS-1) Port B Status Displays the status (Link or No-Link) and the connection type (A-B, B-B, B-M) of the moduleÕs FDDI-1 front panel B port.
9F206-02 Module Specific Information (FNB-2) Configuration Indicates one of the following: ¥ ¥ FNB-2 is inserted (ÒInsertedÓ) on the backplane ring. FNB-2 is isolated (ÒBypassedÓ) from the backplane ring. DAS-2 Status Indicates the status of DAS-2: ¥ ¥ ¥ ¥ ¥ Dual Homed Isolated Thru Twisted Wrapped (DAS-2) Port A Status Displays the status (Link or No-Link) and the connection type (A-A, A-B, A-M) of the moduleÕs FDDI-2 front panel A port.
F206-02 Module Specific Information 3. Use the arrow keys to highlight SAVE at the bottom of the screen, and then press the Return key. When the message ÒSAVED OKÓ appears, the edits you have made are saved. If you exit without saving, the message ÒNOT SAVED -- PRESS SAVE TO KEEP CHANGESÓ appears. If you proceed to exit without saving, your edits will be lost. 4. Exit the screen by using the arrow keys to highlight RETURN, and then pressing the Return key.
9F206-02 Module Specific Information 8