Specifications

Management Module Anomalies
Management Module SRN 6.0 Rev 0 Page 54
SmartSwitch ATM Access Module (9A128-01,
9A426-02)
Corrected Anomalies:
1 The 9A426-02 modules allow access to the Device Topology view now,
and show interfaces in other views.
Known Anomalies:
Problem 1: After a 9A128-01 is placed in a 9000 chassis and
SpectroSERVER is launched, the 9A128-01 is removed from its chassis
container view. A yellow alarm is generated with the following message:
“The device is not associated with a chassis.
Solution: This problem will fixed in a future release.
Problem 2: Attempts to access the Chassis Device view of the modeled
9A128-01 show the error message “Module not contained within Chassis”;
the 9A128-01 is not being placed in the container view of the MMAC-PLUS
chassis.
Solution: Navigate to the chassis view for the container device, then copy
and paste the 9A128-01 into the container view of the MMAC-PLUS
chassis. Now you can access the Chassis Device view. This device is no
longer manufactured.
SPECTRUM
Part Name
Devices
Firmware
Version
MM
Version
SM-CSI1059 SmartSwitch 9A128_01
SmartSwitch 9A426_02
2.04.09 6.0 Rev 0