Specifications

Management Module Anomalies
Management Module SRN 6.0 Rev 0 Page 49
Problem 4: When modeling a 9A6x6 as a standalone, the Chassis Device
view shows CTMifPort icons. The CTMifPort icons should not appear in this
view.
Solution: This is a firmware problem; upgrade to 3.00.04 or a later
firmware version.
Problem 5: Error messages may appear when you attempt to save created
entries within the Static Bridging application’s Static Bridging Table. This
only happens with some SmartSwitch 9000 modules; for example; the
9E133-36, 9E138-36, 9E423-24, and 9F310-02 SmartSwitch models
display the following:
Update failed for the following attributes:
Attribute 0x1194c - Attribute doesn’t exist on
device,0x200000a
Solution: In order for the Static Bridging Table to work correctly, a
“MacAddr.receiveport” entry must be provided. Then, click the Create
Static Database Entry, confirm the”MacAddr.receive” value’s existence,
click Close, and click Save again. This saves the MAC address as a Static
Database Entry, and the error message will not appear.
Problem 6: For the 9T125_08 and 9T122_24, the CsTRing1App’s
Cabletron Token Ring Ring Configuration View shows ?? within the Beacon
State field.
Solution: This is a firmware problem; the 9T125_08 has been deprecated
for 6.0 rev 0.