Specifications
Table Of Contents
- Titlepage
- Notice
- Contents
- Management Module Anomalies
- 3Com FMS/MSH
- 3Com LinkSwitch 1100/3300
- 3Com NetBuilder II
- 3Com PortSwitch Family
- AT & T StarLAN10 SmartHUB
- Bay Centillion 100
- CSX200/400
- Cayman GatorStar Repeater/Router
- Cisco Catalyst
- Cisco Access Server
- Cisco Works Integration
- Cisco Router
- ELS100-24TXG
- EMME/EMM-E6
- ESXMIM (Ethernet Switching Bridge)
- Ethernet Hubs
- FDM
- ForeRunner Series of ATM Switches
- Generic SNMP Devices
- Host HP
- Host Compaq Module
- Host NT Module
- Kentrox DataSMART
- NBR 620, 420, and 220 (Ethernet Bridge Routers)
- RMON Management Module
- RingView for Token Ring
- SEHI Hubs
- SFSmartCell Switch (9A656-04, 9A686-04)
- SmartSwitch 2000 Family
- SmartSwitch 8H02-16
- SmartSwitch 6000 Chassis
- SmartSwitch 6000 Family
- SmartSwitch 9000 Dual Backplane
- SmartSwitch 9000/9500
- Common Anomalies - SmartSwitch 9000/9500
- SmartSwitch ATM - Zeitnet Switch (2500, 6500, 6A000, 9A100)
- SmartSwitch ATM Access Module (9A128-01, 9A426-02)
- SmartSwitch FDDI (9F310-02, 9F426-02, 9F426-03)
- Gigabit Ethernet SmartSwitch SSX (9G5xx-xx)
- SmartSwitch Router (SSR) 250/2000/8000/8600
- SmartSwitch Token Ring MicroLAN Switches (9T122-08, 9T122-24, 9T125-08, 9T125-24)
- SmartSwitch FDDI MicroLAN Switch (9F106-02, 9F116-01, 9F120-08, 9F122-12, 9F125-08, and 9F241-12)
- SmartSwitch STS16 Token Ring
- SynOptics 5000 Hubs
- SynOptics Modules
- TRMM and TRMMIM Token Ring Modules
- TRMM-2 and TRMM-4 Token Ring Modules
- Xylogics Terminal Server II
- Wellfleet Routers
- SPMA (SPECTRUM Portable Management Applications)
- Index

Management Module Anomalies
Management Module SRN 6.0 Rev 0 Page 26
FDM
Known Anomalies:
Problem 1: There are no statistical reports being generated for the
BdgCSIFDM icon.
Solution: Run the reports on the applications for the HubCSIFDDI icon
to review the statistical information; the statistical reports function as
designed.
Problem 2: When you enter “Delete-on-Reset” or “Delete-on-Timeout” in
the Static Database Table, it does not appear, although it does appear in
the CT_Tp_App Table, Transparent Bridge Information Table, and
Forwarding Database Table. Due to this entry not being in the Static Table,
you cannot change the status or use “Invalid” to remove the entry.
Solution: You must reset the FDM or use local management in order to
remove the entry. This problem will be corrected in a future release of the
FDM firmware.
Problem 3: In the Device Topology view of the BdgCSIFDM, the Simplified
Device view shows the FDM in slot 2, regardless of its true position within
the chassis.
Solution: This is a firmware problem; the Device Topology view shows
incorrect information. Once the model has been resolved to the appropriate
place in an EMME or IRM chassis, the FDM model will appear in the
correct slot within both the FDM and EMME/IRM Device views.
SPECTRUM
Part Name
Device
Firmware
Version
MM
Version
SM-CSI1012 FDMMIM
FDMMIM-04
4.07.06 6.0 Rev 0