Specifications

Management Module Anomalies
Management Module SRN 6.0 Rev 0 Page 22
EMME/EMM-E6
Known Anomalies:
Problem 1: The Physical Device view does not show a BRIM inserted into
a device. The view only shows a space where a BRIM can be inserted.
Solution: This problem will be addressed in a future release of
SPECTRUM.
Problem 2: When you attempt to save created entries within the Static
Bridging application’s Static Bridging Table from the EMM-E6, the
following error message may display:
Update failed for the following attributes:
Attribute 0x1194c -
Attribute doesn’t exist on device,0x200000a
Solution: In order for the Static Bridging Table to work correctly, a
MacAddr.receiveport entry must be provided. Before pressing the button to
create the static database entry, confirm the MacAddr.receive value’s
existence.
SPECTRUM
Part Name
Device
Firmware
Version
MM
Version
SM-CSI1004 EMME/EMME -
Routing
3.08.01
1.01.02
6.0 Rev
0
SM-CSI1004 EMM-E6
EMM-E6 ADV
3.22.01
4.01.12
6.0 Rev
0