Specifications
FDM
Anomalies Management Module
26 Software Release Notice 5.0 Rev 1
FDM
Corrected Anomalies:
Known Anomalies:
SPECTRUM
Part Name
Device Firmware
Version
MM
Version
SM-CSI1012 FDMMIM
FDMMIM-04
4.07.06 5.0 rev1
1. Generic Bridging applications no longer show errors in the performance percentages
displayed in the Performance views.
2. If you change the community name of the FDMMIM to anything other than public,
Autodiscovery now models the device as pingable.
Problem 1: There are no statistical reports being generated for the BdgCSIFDM icon.
Solution: Run the reports on the applications for the HubCSIFDDI icon to review the
statistical information; the statistical reports function as designed.
Problem 2: When you enter “Delete-on-Reset” or “Delete-on-Timeout” in the Static Database
Table, it does not appear, although it does appear in the CT_Tp_App Table,
Transparent Bridge Information Table, and Forwarding Database Table. Due to this
entry not being in the Static Table, you cannot change the status or use “Invalid” to
remove the entry.
Solution: You must reset the FDM or use local management in order to remove the entry. This
problem will be corrected in a future release of the FDM firmware.
Problem 3: In the DevTop view of the BdgCSIFDM, the Simplified Device view shows the FDM
in slot 2, regardless of its true position within the chassis.
Solution: This is a firmware problem; the DevTop view is not reporting information properly.
Once the model has been resolved to the appropriate place in an EMME or IRM
chassis, the FDM model will appear in the correct slot within both the FDM and
EMME/IRM Device views.