Common Anomalies - SmartSwitch 9000 Management Modules
Anomalies Management Module
16 Software Release Notice 5.0 Rev 1
Problem 2: Currently, you can create SmartSwitch 9000 models in Location or Organization
views, even though a Contains relation cannot be established with the SmartSwitch
chassis model, and the models do not show up in the Device view of the SmartSwitch.
Solution: Do not create any SmartSwitch 9000 models in the Location or Organization views;
instead create the model in the Topology view and then copy the SmartSwitch
Chassis model from the Lost and Found view into the Location view. The
SmartSwitch chassis model has a Container view which contains Location view icons
for all modeled SmartSwitch modules. This ensures that the proper relationship
between the models exists.
Problem 3: Error messages may appear when you attempt to save created entries within the
Static Bridging application’s Static Bridging Table. This only happens with some
SmartSwitch 9000 modules; for example; the 9E133-36, 9E138-36, 9E302-12,
9E423-24, and 9F310-02 SmartSwitch models display the following:
Update failed for the following attributes:
Attribute 0x1194c - Attribute doesn’t exist on device,0x200000a
Solution: In order for the Static Bridging Table to work correctly, a “MacAddr.receiveport”
entry must be provided. Before pressing the button to create the static database
entry, confirm the”MacAddr.receive” value’s existence, click Close, and click Save
again. This saves the MAC address as a Static Database Entry, and the error
message will not appear. This is a firmware problem.
Problem 4: In the Chassis Device view of any 9000 device the ports do not update when you
attempt to change the Port Display. If you navigate to the Physical Device view and
change Port Display, the Operational Status, Type, and Interface Number fields do
not update and show incorrect information.