Specifications
SPECTRUM Enterprise Manager SmartSwitch 9000/9500 Series
 67 of 145
Error Source
This area of the Repeater Configuration view provides a series of buttons allowing you to select the types of 
errors to include in the error sum. The selectable error types are as follows:
CRC
The number of packets received by the module 
with bad Cyclical Redundancy Checks (CRCs).
Runts
The number of runt packets received by the 
module. A runt packet is one byte less than the 
standard Ethernet frame of 64 bytes (not 
including preamble).
OOW_Colls
The number of collisions out of the standard 
window (51.2µs) due to a network problem.
Alignment
The number of misaligned packets detected by 
the module.
No_Resource
The number of times the module ran out of 
resources (i.e., lack of buffer space) and could not 
accept packets.
Giants
The number of giant packets received by the 
module. A giant packet exceeds 1518 bytes (not 
including preamble).