Specifications
SPECTRUM Enterprise Manager SmartSwitch 9000/9500 Series
28 of 145
Environmental Device View
This view displays the temperature in Fahrenheit
or Celsius (selectable from the Options menu) and
power levels for the devices installed in the
chassis. Figure 11 shows an example of an
Environmental Device view. To access the
Environmental view, select View > Page >
Environmental from one of the following Device
views: Chassis, Backplane, or Physical.
Chassis Environmental Information
This area of the Device view also indicates the
environmental status of the chassis. These panels
and their fields are as follows:
Climate
• Temp - displays the ambient temperature of
the room in which the chassis is located.
- Green - normal, cool, or cold
- Yellow - warm
- Red - hot
- Blue - unknown
• Humidity - displays the humidity value of the
air flowing through the chassis.
- Green - dry, normal, or moist
- Blue - unknown
Fan Status/Speed
• F1 through F4 - display the fan speed in
percent of maximum speed for each of the
four fans in the chassis.
- Green - normal, or testing
- Yellow - unknown
- Red - slow, inoperative, or off
• Auto/Full - allows you to set the fans to
“Auto” (speed controlled by the temperature of
the chassis) or “Full” (speed set to maximum).
Power Subsystem
• Total - displays the maximum power that
could be supplied by the chassis power
supply.
• Used - displays the total power currently
being supplied by the chassis power supply.
• Avail - displays the available power from the
chassis power supply.
• Status - displays the status and type of power
for the chassis: AC, DC or Battery.
- Green - power normal
- Yellow - over current, over voltage, or
under voltage
• Redundancy - displays the source of the
power for the chassis.