Specifications

9031280 E4 Using RMON Views
5-7
Accessing Ethernet Views
Ethernet History
Ethernet History
From the Icon Subviews menu, click on Ethernet History. The Ethernet
History Table presents the RMON History data in tabular form. The RMON
History group records data from the Statistics group over user-defined
intervals and stores it for later retrieval, allowing you to perform trend
analysis of a statistic over time or to isolate periods of time during which a
network event may have occurred.
Figure 5-2. Ethernet History Control Table View
The History Control Table (Figure 5-2) presents the configuration of each
History instance running on the network interface. By default, the RMON
standard specifies 2 instances, having intervals of 1800 seconds and 30
seconds. Each instance features the following fields:
Data SourceInterface being monitored
Interval—The sample collection interval
SizeReq—Maximum number of recorded intervals (buckets) requested
for the sample
Size—The number of buckets currently recorded in the sample
Owner—The person who configured the entry
Status—The status of the control table entry
Note that when the values for SizeReq and Size are identical, the oldest
entries in the History Control Table for that instance will be replaced by the
newest entries.