Installation guide

13
MMAC-Plus Installation Guide
Attaching 9C614 INB Terminator Modules
Two 9C614 INB Terminator Modules must be attached to the rear of the
MMAC-Plus chassis when Interface Modules that use the INB are inserted in the
front of the chassis. These modules provide proper termination for the Internal
Network Bus (INB).
The INB Terminator Modules are attached by following the steps below:
1. Remove the INB Terminator Modules from the shipping box. (Save the box
and packing materials in the event the module must be reshipped.)
2. Hold the INB Terminator Module by the handle and line up the screws that
extend from the module with the screw holes in one of the INB Termination
Connectors on the rear of the MMAC-Plus chassis (Figure 7).
3. Push the INB Terminator Module in gently until the frame of the module
touches the frame of the chassis.
4. Tighten the screws on the INB Terminator Module.
5. Repeat steps 1–4 to attach the second INB Terminator Module.
Figure 7. Attaching the INB Terminator Modules
The INB Terminator Module is designed to fit in either INB Termination Connector on
the MMAC-Plus chassis. If the screws that extend from the module do not line up with
the screw holes on the INB Connector, turn the module over.
NOTE
21
100-125v-12A
200-250v-6A
50-60 Hz
1125_04
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
INB
Termination
Connectors