User`s guide
A-3
EPIM-F2
Transmitter power parameters are listed Table A-2.
Table A-1. EPIM-F2 Receiver Specifications
Parameter Typical Value Worst Case
Worst Case
Budget
Typical
Budget
Receive Sensitivity -30.5 dBm -28.0 dBm Ñ Ñ
Peak Input Power -7.6 dBm -8.2 dBm Ñ Ñ
Table A-2. EPIM-F2 Transmitter Specifications
Parameter Typical Value Worst Case
Worst Case
Budget
Typical
Budget
50/125 µm Þber -13.0 dBm -15.0 dBm 13.0 dB 17.5 dB
62.5/125 µm Þber -10.0 dBm -12.0 dBm 16.0 dB 20.5 dB
100/140 µm Þber -7.0 dBm -9.0 dBm 19.0 db 23.5 dB
Error Rate Better than 10
-10
The transmitter power levels and receive sensitivity levels listed are Peak Power
Levels after optical overshoot. A Peak Power Meter must be used to correctly
compare the values given above to those measured on any particular port. If
Power Levels are being measured with an Average Power Meter, then 3 dBm
must be added to the measurement to correctly compare those measured values
to the values listed (i.e., -30.5 dBm peak=-33.5 dBm average).
NOTE