User`s guide
9C306 System Monitor Operation
3-4
COM1 and COM2 Ports
The 9C306 System Monitor front panel has two RJ45 communication ports for
RS232 serial communication to and from the SmartSwitch 9000-6 Slot. Figure 3-2
illustrates a single RJ45 communication port. COM2 can be conÞgured to run the
Serial Line Internet Protocol (SLIP), Point-to-Point Protocol (PPP), Local
Management via a terminal or modem connection, or monitor an American
Power Conversion Smart UPS. Refer to the SmartSwitch 9000-6 Slot
Module Local
Management UserÕs Guide
for detailed information on conÞguring the COM2 port.
Figure 3-2. RJ45 Communication Port Connector
Table 3-4 details the pinout connections for an RJ45 communication port
connector.
The Ethernet Port Interface Module (EPIM)
The 9C306 System Monitor provides a port for Cabletron Systems EPIMs. The
EPIM provides a direct connection to the internal SMB-10 bus. This connection
can be used for out-of-band graphical SNMP management of the SmartSwitch
9000-6 Slot system or a Telnet session into local management. Any standard
Cabletron Systems EPIM can be installed. Refer to Appendix A for detailed
information on the EPIM.
Table 3-4. Pinout Connections RJ45 Communication Port Connector
Pin Description
1 TRANSMIT
2 DATA CARRIER DETECT
3 DATASET READY
4 RECEIVE
5 SIGNAL GROUND
6 DATA TERMINAL READY
7 REQUEST TO SEND
8 CLEAR TO SEND
Pin 1