7F06-02 FDDI SmartSWITCH™ Interface Module User’s Guide 9031672-01
Notice NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice.
Notice FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
Notice VCCI NOTICE This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI) aimed at preventing radio interference in commercial and/or industrial areas. Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc.
CONTENTS CHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL .........................................................................1-1 1.2 THE 7F06-02 MODULE...........................................................................1-2 1.2.1 Cable Type and FPIMs ..................................................................1-2 1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch ..................................1-3 1.3 FEATURES ...................................
Contents 5.7 PHYSICAL ................................................................................................5-2 5.7.1 Dimensions .....................................................................................5-2 5.7.2 Weight ..............................................................................................
CHAPTER 1 INTRODUCTION Welcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User’s Guide. This guide is a simple reference for installing and using the 7F06-02 Module. Before installing this module, you should carefully read through this manual to gain a full understanding of its capabilities. The 7F06-02 Module is a two port FDDI module. This module connects to a network and the 7X00 SmartSwitch™ Control Module in the 7C03,7C04 or 7C04-R MMAC SmartSwitch via a SmartSwitch bus. 1.
INTRODUCTION 1.2 THE 7F06-02 MODULE The 7F06-02 Module provides two Fiber Optic ports via front panel FPIM modules. 1.2.1 Cable Type and FPIMs The 7F06-02 module has two front panel connectors that interface to the 7X00 Smart Switch Module through the chassis backplane. The front panel connections are standard Cabletron FPIMs. There are two FPIMs for each channel.
INTRODUCTION 7F06-02 SP A F D D I 1 SN P S A B B A F D D I 2 P S A B B Figure 1-1. 7F06-02 Module 1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch The 7F06-02 Module is designed to be installed in the 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch or the 7C04-R Workgroup SmartSwitch.
INTRODUCTION Token Ring to be used with the 7F06-02 Module. These modules provide the capability to share data without the use of external bridges or routers. The 7C03 MMAC SmartSwitch is a unique module that can be installed in an MMAC Series chassis. The 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch are standalone chassis that provide the same functions. 1.3 FEATURES The 7F06-02 Module provides two FDDI ports via front panel FPIMs.
INTRODUCTION 1.4 RELATED MANUALS The manuals listed below should be used to supplement the procedures and other technical data provided in this manual. The procedures will be referenced, where appropriate, but will not be repeated. 7X00 SmartSwitch Control Module User’s Guide 7F06-02 Local Management Appendix 7C03 MMAC SmartSwitch Installation Guide 7C04 Workgroup SmartSwitch Installation Guide 7C04-R Workgroup SmartSwitch Installation Guide 1.
CHAPTER 2 NETWORK REQUIREMENTS Before installing Cabletron Systems 7F06-02 Module, review the network requirements outlined in this chapter. All requirements included in this chapter should be met to ensure satisfactory performance of the 7F06-02 Module. Failure to do so may result in unsatisfactory network performance. Appendix A 2.1 FPIM MODULE SPECIFICATIONS This module uses Fiber Port Interface Modules (FPIM) to provide front panel cable connections. The FPIMs are user-installable. See Section 3.
NETWORK REQUIREMENTS Transmitter power parameters are listed in Table 2-2. Table 2-2. Transmitter Power Parameters Worst Case Budget Parameter Typical Value Worst Case Typical Budget 50/125 µm fiber -13.0 dBm -15.0 dBm 13.0 dB 17.5 dB 62.5/125 µm fiber -10.0 dBm -12.0 dBm 16.0 dB 20.5 dB 100/140 µm fiber -7.0 dBm -9.0 dBm 19.0 dB 23.5 dB Error Rate Better than 10-10 The link distance is up to 2 kilometers on the multimode fiberoptic cable as specified by ANSI MMF-PMD.
NETWORK REQUIREMENTS 2.1.2 FPIM-02 and FPIM-04 The FPIM-02 has an RJ-45 connector supporting an Unshielded Twisted Pair (UTP) connection. The FPIM-04 has an RJ-45 connector supporting a Shielded Twisted Pair (STP) connection. The pinouts for both are listed in Table 2-3. Table 2-3.
NETWORK REQUIREMENTS 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a Single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector. The specifications for both devices are listed in Table 2-4. Table 2-4. FPIM-05 and FPIM-07 Specifications Parameter Typical Minimum Maximum Transmitter Peak Wave Length 1300 nm 1270 nm 1330 nm Spectral Width 60 nm - 100 nm Rise Time 3.0 nsec 2.7 nsec 5.0 nsec Fall Time 2.5 nsec 2.2 nsec 5.
CHAPTER 3 INSTALLATION/REMOVAL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMAC SmartSwitch • 7C04 Workgroup SmartSwitch • 7C04-R Workgroup SmartSwitch. Also included in the chapter are instructions the front panel FPIMs. 3.1 UNPACKING THE 7F06-2 MODULE Unpack the 7F06-2 Module by using the following steps: 1. Carefully remove the module from the shipping box. (Save the box and packing materials in the event the module must be reshipped.) 2.
INSTALLATION/REMOVAL Figure 3-1. Installing an FPIM 3.3 INSTALLING/REMOVING THE 7F06-02 MODULE The following procedure detail the installing and removal procedure for the 7F06-02 module. 3.3.1 Installing in the 7C03 SmartSwitch The 7F06-02 Module is installed in the 7C03 MMAC SmartSwitch using the following steps and referring to Figure 3-2.
INSTALLATION/REMOVAL Notes: The left most slot in the 7C03 MMAC SmartSwitch is reserved for the 7X00 SmartSwitch Module. Before installing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. 1. Remove the blank panel covering the slot in which the module will be installed. All other slots must remain covered to ensure proper airflow and cooling. 2.
INSTALLATION/REMOVAL Note: Before removing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. 1. Use a slotted screwdriver to loosen the two screws that secure the module to the chassis. 2. Locate the two ejector tabs on the module (to the right of the screws on the top and bottom of the module). 3.
INSTALLATION/REMOVAL 3.3.3 Installing in the 7C04 or 7C04-R Workgroup SmartSwitch The 7F06-02 Module is installed in the 7C04 or 7C04-R Workgroup SmartSwitch using the following steps and referring to the appropriate figure. Notes: The top slot in the 7C04 Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module. The bottom slot in the 7C04-R Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module.
INSTALLATION/REMOVAL 1 P S P S SP 2 SN 3 4 7X00 SN PW R MAC ADR SP CP U Figure 3-4. Installing the 7F06-02 Module in the 7C04 Workgroup SmartSwitch FANS 4 SP 7A06-01 SN 3 SP 2 7X00 SN SP SP CPU MAC ADR PWR 7F06-02 1 7X00 SN SP CP U MAC ADR PW R Figure 3-5.
INSTALLATION/REMOVAL 3.3.4 Removing from the 7C04 or 7C04-R Workgroup SmartSwitch The 7F06-02 Module, inserted in the 7C04 or the 7C04-R Workgroup SmartSwitch, can be removed whenever necessary. Follow the steps below and refer to the appropriate figure to remove the module. Note: Before removing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. 1.
INSTALLATION/REMOVAL Screws FANS 4 SN 3 2 1 Ejector Tabs Figure 3-7.
CHAPTER 4 TROUBLESHOOTING The 7F06-02 Module uses LANVIEW, Cabletron Systems built-in visual diagnostic and status monitoring system. With LANVIEW LEDs the status of each transmit and receive port on the 7F06-02 Module can be determined, at a glance. This section discusses the function and purpose of the LEDs on the 7F06-02 Module. Figure 4-1 shows the LANVIEW LEDs of the 7F06-02 Module.
TROUBLESHOOTING Table 4-1 indicates the state of the receive port. Table 4-1. Port Receive LEDs LED Color State Yellow (Flashing) Data activity (flashing to steady on indicates rate) Off No activity, port can be disabled or enabled Table 4-2 indicates the state of the transmit port. Table 4-2.
TROUBLESHOOTING Table 4-3 indicates the state of the A/B Link LEDs. Table 4-3.
CHAPTER 5 TECHNICAL SPECIFICATIONS This chapter includes the technical specifications for Cabletron Systems 7F06-02 module. Cabletron Systems reserves the right to change these specifications at any time without notice. 5.1 STANDARDS IEEE 802.1D IEEE 802.3i 10BASE-T 5.2 EMI The EMI requirements of: • FCC Part 15 Class A • EN 55022 Class A • VCCI Class I 5.3 EMC The EMC requirements of: • EN 50082-1 • IEC 801-2 ESD • IEC 801-3 Radiated susceptibility • IEC 801-4 EFT 5.
TECHNICAL SPECIFICATIONS 5.5 SAFETY It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions. This equipment meets the safety requirements of: • UL 1950 • CSA C22.2 No. 950 • EN 60950 • IEC 950 5.6 SERVICE MTBF >200,000 hours MTTR <0.5 hour 5.7 PHYSICAL 5.7.1 Dimensions 31.1D x 22.9 H x 3.1 W centimeters (12.3 D x 9.0 H x 1.2 W inches) 5.7.2 Weight 5-2 Unit: 1.8 kgs.