Specifications

Chapter 1: Changes to Local Management Screens
1-22 Local Management Supplement
Reset Peak Switch Utilization (Toggle)
Used to reset the Peak Switch Utilization field. The switch may be set to
either YES or NO as described in Section 1.8.1. YES resets the Peak
Switch Utilization field to the current system utilization.
1.8.1 Resetting the Reset Peak Switch Utilization
To set the Reset Peak Switch Utilization field to YES or NO, proceed as
follows:
1. Use the arrow keys to highlight the Reset Peak Switch Utilization
field.
2. Press the SPACE bar to select YES or NO.
3. Use the arrow keys to highlight the SAVE command at the bottom of
the screen.
4. Press ENTER. The message “SAVED OK” displays and the Reset
Peak Utilization counter resets to zero.
1.9 FLASH DOWNLOAD CONFIGURATION SCREEN
The Flash Download Configuration screen, shown in Figure 1-10, enables
the user to download a new image file from a TFTP server to Flash
memory.
Before downloading a new image to the module, load the image onto the
network TFTP server.
To access the Flash Download Configuration screen from the Module
Configuration screen, use the arrow keys to highlight the FLASH
DOWNLOAD CONFIGURATION menu item and press ENTER. The
Flash Download screen displays.
NOTE
The user may also force a download by changing the position
of dipswitch 6 located inside the module. Refer to your
SmartSwitch user’s guide for details.
NOTE
For information on how to set up a workstation as a TFTP
server, refer to the specific workstation documentation.