Specifications

Chapter 1: Changes to Local Management Screens
1-18 Local Management Supplement
12. Use the SPACE bar to select either the ADD or DEL option. Press
ENTER. This adds or deletes the selections for the Source VLAN,
Destination Port, and Frame Format made in steps 1 through 10 and
also updates the screen.
13. Use the arrow keys to highlight SAVE at the bottom of the screen.
Press ENTER. The message “SAVED OK” displays. This saves the
new settings and updates the Source VLAN and Destination Port
read-only fields.
1.7 MODULE CONFIGURATION MENU SCREEN
The Module Configuration Menu screen, Figure 1-8, provides access to
Local Management screens that allow you to configure and monitor
operating parameters, modify SNMP community names, set SNMP traps,
configure switch parameters and configure ports.
The path to the Module Configuration screen is
MAIN MENU/MODULES/SELECT SLOT #/MODULE MENU.
To access the Module Configuration Menu screen from the Module Menu
screen, use the arrow keys to highlight the MODULE
CONFIGURATION menu item and press ENTER. The Module
Configuration Menu screen displays.
TIP
If more than 1 port is being redirected, repeat steps 1
through 12 for each additional setting. Then go to step 13 to
save all the new settings at once.
If an entry is to be changed, delete the entry, save the screen,
then recreate the entry with its new settings.
Any combination, up to 128, of port redirect instances
(configured on the Port Redirect Configuration screen) and/or
VLAN redirect instances (configured on the VLAN Redirect
Configuration screen) can be configured.