General Configuration Screen
6E123-50 and 6E133-49 User’s Guide 5-51
5.15.10 Setting the Management Mode
To set the management mode, perform the following steps:
1. Use the arrow keys to highlight the Management Mode field:
2. Use the SPACE bar to toggle the options (DISTRIBUTED or
STAND ALONE) until the desired mode displays.
3. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-19 displays.
4. Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved and the module reboots.
5.15.11 Configuring the COM Port
The 6E123-50 and 6E133-49 COM ports support the following
applications:
Local Management connections
NOTE
Upon saving the new Management Mode, the module will
reboot.
If the module will be set to STANDALONE, ensure the following
procedures have been completed:
The module has been assigned a unique IP address.
The module has been assigned SNMP community names from
the module SNMP Community Names screen (Section 5.16).
In STAND ALONE management mode, the module does not
use the community names of the 6C105 chassis.
!
CAUTION
Before altering the COM port settings, ensure that a valid IP
address is set for the module or chassis. (Refer to
Section 5.15.1, Setting the IP Address.) Read this entire
COM port configuration section before changing the settings of
the COM port.
NOTE
Refer to the Release Notes included with the 6E123-50 and
6E133-49 to verify which COM Port applications are currently
supported.