Chapter 4: Troubleshooting
4-6 6E123-50 and 6E133-49 User’s Guide
4.3 TROUBLESHOOTING CHECKLIST
If the 6E123-50 and 6E133-49 is not working properly, refer to Table 4-4
for a checklist of possible problems, causes, and recommended actions to
resolve the problem.
Table 4-4 Troubleshooting Checklist
Problem Possible Cause Recommended Action
All LEDs are OFF.
Loss of Power to the
6C105 chassis.
Check the proper connection
of the power cable and its
access to a live outlet.
6E123-50 and 6E133-49
not properly installed.
Check the installation.
No Local
Management
Password screen.
Autobaud enabled.
Press ENTER (RETURN)
(may take up to four times).
Terminal setup is not
correct.
Refer to Chapter 5 for proper
setup procedures.
Improper console cable
pinouts.
Refer to Appendix A for
proper console port pinouts.
Cannot contact the
6E123-50 and
6E133-49 from
in-band
management.
Improper Community
Names Table.
Refer to Section 5.16
for Community Names Table
setup.
6E123-50 or 6E133-49
does not have an IP
address.
Refer to Section 5.15.1 for IP
address assignment
procedure.
Port is disabled. Enable port.
No link to device. Check link to device.
Port(s) goes into
standby for no
apparent reason.
6E133-49 or 6E123-50
detects a looped
condition.
Review network design and
delete unnecessary loops.
User parameters (IP
address, Device and
Module name, etc.)
are lost when the
6E133-49 or
6E123-50 is
powered down or
the front panel
RESET button is
pressed.
Mode switch (7), NVRAM
Reset, was changed
sometime before either
cycling power or
pressing the RESET
button, causing the
user-entered parameters
to reset to factory default
settings.
Reenter the lost parameters
as necessary. Call the
Cabletron Systems Global
Call Center if problem
continues.