Title Page SWPIM-E1 Installation Guide LNK STS 9033059-02 SWPIM-E1
Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice.
Notice CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE FOLLOWING GEOGRAPHICAL REGIONS: CANADA MEXICO CENTRAL AMERICA SOUTH AMERICA BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Cabletron Systems, Inc.
Notice If the Program is exported from the United States pursuant to the License Exception TSR under the U.S.
Notice CABLETRON SYSTEMS SALES AND SERVICE, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE UNITED STATES OF AMERICA AND BY UNITED STATES OF AMERICA GOVERNMENT END USERS. BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Cabletron Systems Sales and Service, Inc.
Notice If the Program is exported from the United States pursuant to the License Exception TSR under the U.S.
Notice CABLETRON SYSTEMS LIMITED PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR THE USE OF THE PRODUCT IN THE FOLLOWING GEOGRAPHICAL REGIONS: EUROPE MIDDLE EAST AFRICA ASIA AUSTRALIA PACIFIC RIM BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT.
Notice If the Program is exported from the United States pursuant to the License Exception TSR under the U.S.
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): Manufacturer’s Name: Manufacturer’s Address: European Representative Name: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: 89/336/EEC 73/23/EEC Cabletron Systems, Inc. 35 Industrial Way PO Box 5005 Rochester, NH 03867 Mr. J.
CONTENTS INTRODUCTION Using This Guide ............................................................................xi Structure of This Guide...................................................................xi SWPIM-E1 Features...................................................................... xii Related Manuals........................................................................... xiii Document Conventions ................................................................ xiv Getting Help...........
Contents x SWPIM-E1 Installation Guide
INTRODUCTION Only qualified personnel should perform installation procedures. Welcome to the Cabletron Systems SWPIM-E1 Installation Guide. This manual gives an introduction to the SWPIM-E1, lists features and capabilities, details the cabling pinouts, and explains how to install the SWPIM-E1. The SWPIM-E1 provides a full and fractional E1 interface for a host platform designed to receive the SWPIM (Sliding WAN Physical Interface Module) architecture.
Introduction Appendix A, Specifications, contains information on functionality and operating specifications, connector pinout for the SWPIM-E1, environmental requirements, and physical properties. SWPIM-E1 FEATURES Interfaces The SWPIM-E1 can be installed into any Cabletron Systems product that supports the SWPIM architecture, such as the SSR-600, or the HSIM-SSR-600. Using software, the SWPIM-E1 is user-manageable through the host platform.
Introduction The E1 Data Service Unit (DSU) meets the following specs: • E1 Framing Formats: FAS and CAS, with or without CRC4 • FAS mode: Payload bandwidth is 1.984 Mbps • CAS mode: Payload bandwidth is 1.920 Mbps (channel 16 is reserved for the signaling channel) • Line Coding: HDB3 or AMI • Supports both national and international bits for datalink LEDs and Statistics The SWPIM-E1 has two LEDs, to indicate link and status conditions. Refer to Chapter 1 for more details.
Introduction Cabletron Systems applicable software manuals for the SSR-600 and the HSIM-SSR-600 host platforms (Cabletron Routing Software Manuals): Bridging Configuration Guide Event Logging System Message Guide Network Interface Operations Guide Routing Protocols Reference Guide Routing Protocols User’s Guide System Software Guide ClearVISN Routing Configurator User’s Guide Systems Network Architecture Guide Quick Reference Guide DTF (Data Trace Facility) User Guide DOCUMENT CONVENTIONS The following co
Introduction GETTING HELP For additional support related to this device or document, contact Cabletron Systems using one of the following methods: World Wide Web http://www.cabletron.com/ Phone (603) 332-9400 Internet mail support@cabletron.com FTP ftp://ftp.cabletron.com/ anonymous your email address Login Password To send comments or suggestions concerning this document, contact the Cabletron Systems Technical Writing Department via the following email address: TechWriting@cabletron.
Introduction xvi SWPIM-E1 Installation Guide
CHAPTER 1 INSTALLATION Only qualified personnel should install the SWPIM-E1. This chapter covers the following items: • Unpacking the SWPIM-E1 (Section 1.1) • Installing the SWPIM-E1 into the host platform (Section 1.2) • A description of the LANVIEW LED indications (Section 1.3) • Connecting the SWPIM-E1 to the network (Section 1.4) • What to do once the SWPIM-E1 is installed (Section 1.5) 1.1 UNPACKING THE SWPIM-E1 Use static electricity precautions when handling the SWPIM-E1. 1.
Chapter 1: Installation 1.2 INSTALLING THE SWPIM-E1 The SWPIM-E1 can be installed in any available open slot in the host platform. To install the SWPIM-E1, proceed as follows: 1. Unfasten the screw and remove the blank panel covering the slot in the host platform in which the SWPIM-E1 will be installed. See Figure 1-1. NOTE It is not necessary to power down the host platform to install the SWPIM-E1. 2. Ensure that the antistatic wrist strap is attached and used as recommended.
Installing the SWPIM-E1 Rail Guides Host Platform View of Host Connector End of SWPIM-E1 SWPIM-E1 Network Connector End Thumbscrew LNK STS SWPIM-E1 3059 Figure 1-1 Installing the SWPIM-E1 into the Host Platform 7. Fasten the SWPIM-E1 with the thumbscrew. 8. Replace power to the host platform, if necessary. Check to see that the host platform LED indicators go to their normal configuration. If they do not, remove the SWPIM-E1 from the host platform and contact Cabletron Systems.
Chapter 1: Installation 1.3 LANVIEW LED INDICATIONS Refer to Table 1-1 for the link LED indications for the SWPIM-E1. Table 1-1 Link LED Color Indication Off Disabled or Not Configured Red No Link Amber Transmit or Receive Traffic Green Port is Active Blinking Green Port is in Test Mode Refer to Table 1-2 for the status LED indications for the SWPIM-E1.
Connecting to the Network 1.4 CONNECTING TO THE NETWORK Figure 1-2 depicts a typical configuration for the SWPIM-E1. Site 1 SSR-600 WAN Cloud SWPIM-E1 Site 2 SSR-600 SWPIM-E1 Figure 1-2 1.5 SWPIM-E1 Typical Configuration COMPLETING THE INSTALLATION After installation, the SWPIM-E1 will need to be configured for the network. Refer to the host platform software documentation to set up and manage the SWPIM-E1.
Chapter 1: Installation 1-6 SWPIM-E1 Installation Guide
APPENDIX A SPECIFICATIONS This section describes the environmental specifications and safety and approval requirements for the SWPIM-E1. Cabletron Systems reserves the right to change these specifications at any time without notice. Pinouts and the E1 cable are also listed in this appendix. A.1 PHYSICAL PROPERTIES Dimensions: 1.91 H x 5.40 W x 19.05 D (cm) 0.75 H x 2.125 W x 7.50 D (in) Weight (Unit): .068 kg (0.
Appendix A: Specifications A.2.1 Pinouts for the E1 Interface Connector The network interface pin assignments for the network connector are listed in Table A-1. Table A-1 A.3 Pinouts for the E1 Interface Connection Pin Signal 1 Receive Ring 2 Receive Tip 3 Shield Ground 4 Transmit Ring 5 Transmit Tip 6 Shield Ground 7 Shield Ground 8 Shield Ground E1 CABLE ASSEMBLY Table A-2 lists Cabletron Systems part numbers for the interface cables for the SWPIM-E1.
Environmental Requirements The following table provides connector information for the SWPIM-E1 interface cable. Table A-3 SWPIM-E1 Connector Information Cabletron Systems interface cable part number 9372095-L Description E1 line interface cable Connector 1 RJ45 Connector 2 RJ45 A.4 ENVIRONMENTAL REQUIREMENTS Operating Temperature: +5° to +40°C (41° to 104°F) Non-operating Temperature: -30° to +90°C (-22° to 194°F) Operating Humidity: 5% to 90% (Non-condensing) A.
Appendix A: Specifications A-4 SWPIM-E1 Installation Guide