User`s guide

7-10
Diagnostics and Troubleshooting
Check for loose port connections. Check all connectors to the
modules (especially twisted pair connectors, which may be
fragile).
Check to make sure all the modules are firmly connected; check
all the screws are fully tightened.
Number of carrier losses is increasing. This indicates that the
transceiver is not present or the transceiver's 10BASE-T
connection is suspect. Check the transceivers to ensure they are
firmly connected.
Number of total collisions has dramatically increased. Check the
BNC transceiver, it may be lacking a terminator or its BNC
connector may be touching another transceiver's BNC
connector. Packets that are not being bridged/routed correctly
can also cause total collisions to increase. Verify the aging time
and the IP addresses of the ATX.
Make sure UTP Transceivers are not pre-10BASE-T.
DEC Broadband AUI Transceiver is not supported by the ATX.
Unix spray command loses packets if workstations are busy.
RESET button is depressed in an effort to reset the module. The
RESET button merely takes the module offline. To reset the
module or to bring it online use LCM. (On newer modules the
button is labelled OFFLINE, rather than RESET.)
7.5.4 ATX Has Rebooted
Check the NMS configFatalErr trap to determine the reason
for the reboot.
7.5.5 ATX Does Not Respond To NMS
Check status of ports using LCM.
See if Spanning Tree topology is stable on LCM.