Problem 18: In the Stack Link view on Windows NT, the pipe connecting
the two models is split horizontally, with one half black and one half gold.
Solution: This is a known Neuron Data bug (ND defect # 11069) and not
a bug with SPECTRUM. The pipe still returns important data since colors
are present.
Problem 19: On Windows NT, SPECTRUM applications do not respond to
“Minimize All Windows.”
Solution: This is a Neuron Data problem ND bug #10530 and
SPECTRUM case #42435. Although not a problem with SPECTRUM itself,
SPECTRUM is nevertheless working with Neuron Data on this problem.
Problem 20: On the Solaris 2.7 platform, you may receive an error
message when invoking MibTools. The message is similar to the following:
Error restoring application state.
Version mismatch between stored and application class for:
<location>
Hit OK
Solution: A new JMibTools-specific file,
MibTools-<username>.ser, (where
<username> is your login name) has been created in your home directory.
Remove
MibTools-<username>.ser and re-invoke MibTools. This problem will be
corrected in a future release of SPECTRUM.
Problem 21: When using RMON and the RMON Suite, if you click the
Guide button, nothing happens.
Solution: The documentation may either be not installed or not
accessible. This problem is being studied and will be corrected in the 6.0
release of SPECTRUM.
Problem 22: When working in JAVA-based applications such as
AutoDiscovery and MibTools, you are able to cut/copy and paste multiple
lines from an Xterm window into JAVA-based text fields that only accepts
one value such as the “IP Address List”, or the “Community String.” When
you do this, you get unwanted results such as lists of text lines or IP