Specifications
Configuration Views
Device Management Page 50 SmartSwitch 2000
Link Error Monitor Count
The aggregate link error monitor count. This
count is set to zero on station power up and
increments each time the port’s link error monitor
detects an error. An increasing link error monitor
count usually indicates a problem with the
connectors or the cable between this port and the
node.
Link Error Rate Cutoff
The link error rate threshold at which a link
connection is flagged as faulty and the port
disabled by SMT. The default link error rate cutoff
threshold is 7, which represents 12.5 bit errors
per second.
Link Error Rate Alarm
The link error rate threshold above which an
alarm for the port will be generated. The default
link error rate alarm threshold is 8, which
represents 1.25 bit errors per second.
Link Error Monitor Reject Count
The link error monitor count of the times the link
has been rejected.