Specifications
Configuration Views FddiMAC Device Configuration View
Device Management Page 39 SmartSwitch 2000
MAC Configuration
The actual configuration of the station. Table 18 lists
the possible configurations and their descriptions.
Table 17: FDDI Ring States
Ring States Description
Isolated The concentrator is not attached to the
ring.
Non-Op The concentrator is attempting to enter
the ring.
Ring-Op The ring is operational.
Detect The claim/beacon process of the FDDI
ring protocol has exceeded one second.
This indicates a potential problem.
Non-Op-Dup The ring failed to complete the
claim/beacon process because a
duplicate FDDI address has been
detected.
Ring-Op-Dup The ring is operational, but a duplicate
FDDI address has been detected.
Directed The claim/beacon process did not
complete within nine seconds. The
concentrator is now sending directed
beacons to indicate a problem.
Trace A problem has been detected with the
station or its upstream neighbor. A
trace is being sent to notify the
upstream neighbor of the problem. The
concentrator and all stations between
the concentrator and its upstream
neighbor can perform self-tests.
Table 18: SMT MAC Configurations
Ring
States
Description
Isolated The path is not inserted into any path.
Local_A The A port is inserted into a local path and
the B port is not.
Local_B The B port is inserted into a local path and
the A port is not.
Local_AB Both A and B are inserted into a local
path.
Local_S The S port is inserted into a local path.
Wrap_A The secondary path is wrapped to the A
port.
Wrap_B The secondary path is wrapped to the B
port.
Wrap_AB The primary path is wrapped to the B port
and the secondary path is wrapped to the
A port.
Wrap_S The primary port is wrapped to the S port.
C_Wrap_A The primary and secondary paths are
joined internally in the station and
wrapped to the A port. Regarding token
flow, all resources on the secondary path
precede those of the primary path.