Specifications

MRXI-22/24 Events and Alarms
Event and Alarm Messages MRXI-22/24
4-6 Management Module Guide
CsEvFormat/Event000d011b
{d "%w- %d %m-, %Y - %T"} Environment
Voltage Low condition has been detected
by power supply in slot {I 1} of {m} ({t}).
(event [{e}])
CsPCause/Prob000d011b
1) The power supply may be defective. 2)
An AC power failure has occurred into the
power supply module.
CsEvFormat/Event000d011c
{d "%w- %d %m-, %Y - %T"} Environment
Temperature Normal condition for
module in slot {I 1} reported by {m} ({t}).
(event [{e}])
CsPCause/Prob000d011c
A chassis or cooling system problem at
this device's location has been corrected.
CsEvFormat/Event000d011d
{d "%w- %d %m-, %Y - %T"} Environment
Voltage Normal, all power supply voltages
have returned to NORMAL for {m} ({t}).
(event [{e}])
CsPCause/Prob000d011d
The problem with the power supply
module or AC power feed has been
corrected and the unit is now functioning
normally.
CsEvFormat/Event000d011e
{d "%w- %d %m-, %Y - %T"} A fan in the
system's chassis has failed or is operating
at an abnormal RPM rate, has been
detected by {m} ({t}). (event [{e}])
CsPCause/Prob000d011e
1) One or more fans in the fan tray
assembly have failed. 2) The fan tray has
been removed.
CsEvFormat/Event000d011f
{d "%w- %d %m-, %Y - %T"} A fan in the
system's chassis has resumed normal
operation, has been detected by {m} ({t}).
(event [{e}])
CsPCause/Prob000d011f
The problem previously detected with the
fan assembly has been corrected and the
unit is now functioning normally.
CsEvFormat/Event000d0121
{d "%w- %d %m-, %Y - %T"} Broadcast
threshold exceeded {I 1} total packets in {I
3} seconds on the module in slot {I 5} of
{m} ({t}). (event [{e}])
CsPCause/Prob000d0121
The broadcast (packets per time interval)
threshold has been exceeded for the given
module.
CsEvFormat/Event000d0122
{d "%w- %d %m-, %Y - %T"} Broadcast
threshold exceeded {I 1} total packets in {I
3} seconds on port {I 7} on the module in
slot {I 5} of {m} ({t}). (event [{e}])
CsPCause/Prob000d0122
The broadcast (packets per time interval)
threshold has been exceeded for the given
port.
CsEvFormat/Event000d0125
{d "%w- %d %m-, %Y - %T"} System
Voltage Low condition has been detected
by {m} ({t}). (event [{e}])
CsPCause/Prob000d0125
1) The power supplies are failing. 2) There
is not enough power available to the host
modules.
Table 4-1. MRXI-22/24 Events and Alarms (Continued)