Specifications

9030751 E7 Event and Alarm Messages
4-3
MRXI-22/24 Events and Alarms
CsEvFormat/Event000d0105
{d "%w- %d %m-, %Y - %T"} New source
address {X 5}, is detected on {m} ({t}), port
{I 3} of module in slot {I 1}. (event [{e}])
CsPCause/Prob000d0105
1) The device is new. 2) The device has
been powered up but has not transmitted
a packet with the aging time period.
CsEvFormat/Event000d0106
{d "%w- %d %m-, %Y - %T"} Source
address {X 5}, has timed out on port {I 3}
of the module in slot {I 1} of {m} ({t}).
(event [{e}])
CsPCause/Prob000d0106
A device linked or not linked to this port
has not transmitted a packet during the
aging time period, and has been removed
from the source address table of the
device.
CsEvFormat/Event000d0107
{d "%w- %d %m-, %Y - %T"} Device
configuration change reported by {m} ({t}).
The module in slot {I 1} has been removed.
(event [{e}])
CsPCause/Prob000d0107
A module within this hub has been
removed or has failed.
CsEvFormat/Event000d0108
{d "%w- %d %m-, %Y - %T"} Device
configuration change reported by {m} ({t}),
An (EPIM) has been inserted into slot {I 1}
of the MMAC. (event [{e}])
CsPCause/Prob000d0108
A module has been inserted into this hub.
CsEvFormat/Event000d0109
{d "%w- %d %m-, %Y - %T"} Network
configuration change reported by {m} ({t}).
Port {I 3} in slot {I 1} has failed
redundancy polling and has switched to a
backup port. (event [{e}])
CsPCause/Prob000d0109
1) The device(s) have failed or have been
powered down. 2) A cable fault from the
active port to the polled device has
occurred.
CsEvFormat/Event000d010a
{d "%w- %d %m-, %Y - %T"} Network
configuration change reported by {m} ({t}).
Port {I 3} in slot {I 1} has now become
active as the result of a redundancy poll
failure. (event [{e}])
CsPCause/Prob000d010a
The polled device has been communicated
with via a backup port and the port is now
active. The other ports in this redundant
circuit are now designated as backup and
are turned off to prevent data loops on the
network.
CsEvFormat/Event000d010b
{d "%w- %d %m-, %Y - %T"} Redundancy
diagnostics of {m} ({t}), indicate that the
redundant link for module {I 1}, port {I 3}
has failed. (event [{e}])
CsPCause/Prob000d010b
The cable segment connected to the port
has a cable fault.
Table 4-1. MRXI-22/24 Events and Alarms (Continued)