Specifications
1
Doc. No.
Copyright © 1994
Cisco Systems, Inc.
All rights reserved.
Installing and Configuring
the Environmental Monitor Card
in the AGS+ Chassis
78-0899-03
Product Number: CSC-ENVM= and MC-ENVM-V2.2=
Description of the CSC-ENVM Environmental Monitor Card
The CSC-ENVM card is included in all AGS+ configurations and is required for system operation.
The CSC-ENVM is not an optional card, and is currently shipping with Microcode Version 2.2
(Product Number MC-ENVM-V2.2=), which is backward compatible with the earlier system
software versions referred to in this document. The CSC-ENVM serves a number of purposes for the
AGS+, including monitoring power supply voltages ( 5 volts [V] and 12V) and high temperature
conditions (chassis intake air temperature is measured, and exhaust air flow is measured). Air flow
and temperature monitors provide two levels of protection: warning flags displayed by network
management software and faults that cause the system to be shut down. With System Software
Version 8.3(3) or later and CSC-ENVM Microcode Version 2.2 or later, network management
software can also poll and display power supply voltage and air temperature to help predict system
problems through the use of sensors on the CSC-ENVM. An overvoltage fault or a high-temperature
fault will cause the CSC-ENVM to shut down the system.
The states of processing operations are displayed on four light emitting diodes (LEDs) on the front
edge of the CSC-ENVM. The 15-pin connector on the right front edge of the CSC-ENVM card can
be attached to the optional Flash memory card that provides nonvolatile storage of bootable multiple
system software images.
The CSC-ENVM card also functions as an intelligent slave input/output card, as well as a memory
card. The CSC-ENVM serves the same memory functions as the CSC-MT card, thus making
additional Multibus memory cards unnecessary in the AGS+. The CSC-ENVM provides
64 kilobytes (KB) of Multibus memory and 64 KB of nonvolatile random access memory
(NVRAM). (See the note in the section “Replacing the CSC-ENVM Card.”)
Note The show environment command is available as of System Software Version 8.3(3) or later.
The show environment last command is available as of System Software Version 9.0 or later. Each
command requires CSC-ENVM Microcode Version 2.2 (MC-ENVM-V2.2=) or later.