Specifications

Appendix 2 n : 1 Connection (Multi-link 2) App2-3
* When the terminal converter “TC485” is not used, install jumpers between +RD/+SD and
RD/SD.
For V706:
For V706 + DU-01, refer to “For V7 Series:” above.
(a) Connection between PLC V706 master station (MJ2)
The communication parameter setting and connecting method are the same as those for 1 : 1
connection.
(Refer to “Chapter 2” to “Chapter 33.”)
(b) Connection between V706 master station (MJ1) V706 slave station (MJ2)
The connecting port of the V706 master station should be MJ1. Select [Modular Jack] from the
[System Setting] menu. Select [Multi-Link] for [Modular Jack 1].
The multi-link 2 master cable (b) (V6-MLT) is 3 m long.
From the M706 master station, the V6-MLT cable is connected to the terminal block. From the
terminal block, cables are routed in the direction of “(c)” and “(d).”
(C) Connection between terminal block V706 slave station (MJ2)
The connecting port of the V706 slave station should be MJ2.
A V6-TMP cable (3 m long) is used as cable “(c).”
Since MJ2 is adapted to 4-wire connection, it is necessary to change the signal connection
from 4-wire to 2-wire for multi-link 2 connection. Connect the slave station to the terminal
block via 4-wire connection and then install jumpers between +SD and +RD and between SD
and RD on the terminal block (as shown in the wiring diagram on the following page).
(b) (c) (d) (e)
FG
+SD
SD
+RD
RD
SG
SG
SG
+
+
FG
+SD
SD
+RD
RD
SG
FG
+SD
SD
+RD
RD
SG
Signal
Name
To be installed by the user
Terminal block
V7 slave station
CN1 + TC485
V7 slave station
CN1 + TC485
V7 slave station
CN1 + TC485
V7 master station
MJ1/2
Terminating resistance
(OFF)
Terminating resistance
(OFF)
Terminating resistance
(ON)
Terminating resistance
(ON)
Signal
Name
Signal
Name
Signal
Name
PLC
MJ2
(a)
(b)
(d) (e)
MJ2MJ2
MJ2 MJ1
*1 *1 *1
(c) (c) (c)
*2 *2 *2
Communications between V706: RS-485 (2-wire), maximum length = 500 m
V706 master station
(= Local Port 1)
V706 slave station
(= Local Port 2)
V706 slave station
(= Local Port 3)
V706 slave station
(= Local Port 4)
Terminal block
*1 0.5 m recommended (1.0 m maximum)
*2 Set the slide switches on the V706 slave stations to the lower position: RS-422.
*3 Use twisted-pair cables of 0.3 mm sq. or greater between terminal blocks.