Specifications
Appendix 2 n : 1 Connection (Multi-link 2) App2-3
* When the terminal converter “TC485” is not used, install jumpers between +RD/+SD and
−RD/−SD.
For V706:
For V706 + DU-01, refer to “For V7 Series:” above.
(a) Connection between PLC ↔ V706 master station (MJ2)
The communication parameter setting and connecting method are the same as those for 1 : 1
connection.
(Refer to “Chapter 2” to “Chapter 33.”)
(b) Connection between V706 master station (MJ1) ↔ V706 slave station (MJ2)
The connecting port of the V706 master station should be MJ1. Select [Modular Jack] from the
[System Setting] menu. Select [Multi-Link] for [Modular Jack 1].
The multi-link 2 master cable (b) (V6-MLT) is 3 m long.
From the M706 master station, the V6-MLT cable is connected to the terminal block. From the
terminal block, cables are routed in the direction of “(c)” and “(d).”
(C) Connection between terminal block ↔ V706 slave station (MJ2)
The connecting port of the V706 slave station should be MJ2.
A V6-TMP cable (3 m long) is used as cable “(c).”
Since MJ2 is adapted to 4-wire connection, it is necessary to change the signal connection
from 4-wire to 2-wire for multi-link 2 connection. Connect the slave station to the terminal
block via 4-wire connection and then install jumpers between +SD and +RD and between −SD
and −RD on the terminal block (as shown in the wiring diagram on the following page).
(b) (c) (d) (e)
FG
+SD
SD
+RD
RD
SG
SG
SG
+
+
FG
+SD
SD
+RD
RD
SG
FG
+SD
SD
+RD
RD
SG
Signal
Name
To be installed by the user
Terminal block
V7 slave station
CN1 + TC485
V7 slave station
CN1 + TC485
V7 slave station
CN1 + TC485
V7 master station
MJ1/2
Terminating resistance
(OFF)
Terminating resistance
(OFF)
Terminating resistance
(ON)
Terminating resistance
(ON)
Signal
Name
Signal
Name
Signal
Name
PLC
MJ2
(a)
(b)
(d) (e)
MJ2MJ2
MJ2 MJ1
*1 *1 *1
(c) (c) (c)
*2 *2 *2
Communications between V706: RS-485 (2-wire), maximum length = 500 m
V706 master station
(= Local Port 1)
V706 slave station
(= Local Port 2)
V706 slave station
(= Local Port 3)
V706 slave station
(= Local Port 4)
Terminal block
*1 0.5 m recommended (1.0 m maximum)
*2 Set the slide switches on the V706 slave stations to the lower position: RS-422.
*3 Use twisted-pair cables of 0.3 mm sq. or greater between terminal blocks.
*3
Terminal block Terminal block