Specifications

7. Application Instructions
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
7-54
102 FWD
S1 S2 n
VFD-A series drive forward
command
Bit device Word device
Device
Operand
X Y M S K H KnX KnY KnM KnS T C D E F
S1
ϨϨ Ϩ
S2
ϨϨ Ϩ
n
ϨϨ
103 REV
S1 S2 n
VFD-A series drive reverse
command
Bit device Word device
Device
Operand
X Y M S K H KnX KnY KnM KnS T C D E F
S1
ϨϨ Ϩ
S2
ϨϨ Ϩ
n
ϨϨ
104 STOP
S1 S2 n
VFD-A series drive stop
command
Bit device Word device
Device
Operand
X Y M S K H KnX KnY KnM KnS T C D E F
S1
ϨϨ Ϩ
S2
ϨϨ Ϩ
n
ϨϨ
FWD/REV/STOP are communication commands for Delta A/H series
drive, make sure to use the communication overtime setting (D1129)
when applying these commands.
S1
Communication address: K00000~K00031.
S2
ACdrive master frequency setting for VFD-A series: setting of
K0000 to K4000 represents 0.0Hz to 400.0Hz. For H series AC drive,
the setting of K0000 to K1500 represent 0Hz to 1500Hz.
n
command object, n=1 is for one drive. n=2 communicates to all
drives connected.
The feedback data from perpherial equipment will be saved in D1070
to D1080. PLC will check the data after the SAVE function is complete.
If there is an error, M1142 will be ON.
105 RDST
S1 n VFD-A series drive status read
Bit device Word device
Device
Operand
X Y M S K H KnX KnY KnM KnS T C D E F
S1
ϨϨ Ϩ
n
ϨϨ
RDST is a read status instruction used with the VFD-A series drive.
S1
, Communication address: K00000 to K00031.
n
Status object.
n = 0 Frequency command
n = 1 Output frequency
n = 2 Output current
n = 3 Operation command
There are 11 words in the feedback command message saved in the low
byte of address D1070 to D1080.
106 RSTEF
S1 n
VFD-A series drive reset
command
Bit device Word device
Device
Operand
X Y M S K H KnX KnY KnM KnS T C D E F
S1
ϨϨ Ϩ
n
ϨϨ