Operator`s manual

10 10
4 Operation
4.1 Operator Controls
Power Switch
The power switch is located on the left-hand side of the printer.
Position 0: Off
Position I: On
DIP Switches
i
Switch off the printer before setting the DIP switches.
DIP switch Functions Remarks
1 2 3 4 5 6 7 8
DIP ONI
ON OFF
1 ON: Direct thermal print
OFF: Thermal transfer print
Print settings
Default: OFF
2 ON:
Enables back feed (tear-off mode)
OFF: Disables back feed
Back feed (tear-off mode)
Default: OFF
3 Reserved Always OFF
4 Reserved Always OFF
5 Reserved Always OFF
6 Reserved Always OFF
7, 8 8 | 7
0 | 0 – 9600,n,8,1
0 | 1 – 19200,n,8,1
1 | 0 – 38400,n,8,1
1 | 1 – 57600,n,8,1
Serial interface RS 232
Baud rate setting
0: OFF, 1: ON
Default: 00
Control Panel
The operating panel consists of three LEDs and three multifunction buttons.
LEDs
They indicate the status of the printer.
READY Lights Standard printer status
MEDIA Lights Standard printer status
Flashes simultaneously with READY Media roll has run out
Flashes PAUSE status
RIBBON Lights Standard printer status
Off Direct thermal printing
(no transfer ribbon inserted)
Flashes simultaneously with READY Ribbon roll has run out
Multifunction buttons
The printer is either in standard or system mode.
Normal mode System mode
PAUSE Pause print job
Continue print job after pause
Self-test
FEED Feed one label Calibrating the media sensor
CANCEL Cancel print job
Continue printing after rectifying fault
Reset