User Manual
EEPROM/Infor mation/
EEPROM!memory!map!specific!data!field!description!is!as!below:!
Digital/Diagnostic/Monitoring/Interface//
Five!transceiver!parameter!values!are!monitored.!The!following!table!defines!the!monitored!parameter's!
accuracy.!
Parameter
Range!
Accuracy!
Calibration!
Temperature!
0°C!to!70°C!(C)!
±3°C!
Internal!
-40°C!to!85°C!(I)
Voltage!
2.97V!to!3.63V!
±3%!
Internal!
Bias!Current!
0mA!to!100mA!
±10%!
Internal!
TX!Power!
-9dBm!to!-4dBm
±3dB!
Internal!
RX!Power!
-18dBm!to!0dBm
±3dB!
Internal!