Service manual

_____________________
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
LABEL PLACEMENT ON GRID OR AIR BLOW YOU MAY HAVE TO MASK OFF
LABEL PAD NOT CONSISTENT IMPROPER VACUUM THE HOLES NOT USED BY THE LABEL
ON THE INSIDE OF THE VACUUM BOX
YOU CAN ADD MORE VACUUM
BY TURNING THE VAC SWITCH TO HIGH
TAMP ADJUST AIR PRESSURE
IMPROPER VACUUM
BOTH REPLACE LABEL ROLL
ADHESIVE STRINGS ON LABEL
AND LINER
BOTH REFER TO PEEL EDGE ALIGNMENT
PEEL EDGE OUT OF ADJUSTMENT IN THE LABELER SET UP SECTION
BOTH EXAMINE AND CORRECT
INCORRECT EXTENDED AIR ASSIST TIME
BOTH REFER TO AIR ASSIST SET UP
AIR ASSIST TUBE NOT IN THE LABELER SET UP
ALIGNED PROPERLY SECTION
LABEL FAILS TO LEAVE THE LABEL AIR BLOW SWITCH TO LOW ON VAC SWITCH
GRID OR LABEL PAD TOO MUCH VACUUM
REMOVE MASKING
BOTH AIR BLAST TIME TOO SMALL
NO AIR BLAST
IF BAD VALVE; REPLACE
AIR BLOW INSPECT AND CORRECT
INCORRECT AIR JET PATTERN
81