PROBLEM POSSIBLE CAUSE SOLUTION 
WITH THE POWER SWITCH ON,  POWER CORD DEFECTIVE OR UNPLUGGED INSPECT AND CORRECT 
NO COOLING FAN; NO DISPLAY     
  AC FUSE BLOWN  DETERMINE CAUSE AND REPLACE FUSE
WITH THE POWER SWITCH ON,  DISPLAY CABLE NOT PLUGGED IN TO  RECONNECT CABLE 
COOLING FAN ON; NO DISPLAY  THE BACK OF THE APPLICATOR   
  DISPLAY PORT SETTINGS INCORRECT  LOCATE SW1 NEAR THE AIR FILTER 
MAKE SURE SWITCHES 1 & 6 ARE UP 
  LOSS OF 12 VDC  CALL A FACTORY REPRESENTATIVE 
  DEFECTIVE CABLE  REPLACE CABLE 
  DEFECTIVE DISPLAY BOARD  REPLACE DISPLAY BOARD 
LABEL LINER BREAKING  LABELS ARE THREADED INCORRECTLY  SEE THREADING DIAGRAM 
  BAD ROLL OF LABELS  REPLACE LABEL ROLL 
  SIDE NICKS IN LINER;  REPLACE LABEL ROLL 
  HEAVY DIE CUT ON LINER   
  ROLLER COLLARS ARE STRESSING  CHECK TO MAKE SURE GUIDE COLLARS
  THE LABEL STOCK  LINE UP WITH UNWIND 
    SHOULD HAVE 1/64" CLEARANCE 
    BETWEEN LABEL STOCK AND COLLAR 
  ADHESIVE BUILD-UP ON PEEL EDGE  CLEAN PEEL EDGE SURFACE 
  PEEL BAR TENSION SPRING TOO TIGHT  RELEASE SPRING TENSION 