Service manual
___________________________
GENENRAL MAINTENANCE
!!WARNING!! DISCONNECT THE POWER AND AIR TO MACHINE
BEFORE DOING THE FOLLOWING PROCEDURES.
INJURIES COULD OCCUR FROM MOVING PARTS OR
ELECTRICAL SHOCK.
DRIVE BELT ADJUSTMENT
1. Remove all AC power and air to the machine.
2. Remove the lower stainless cover.
3. Remove the air lines interconnecting the two sides of the applicator to gain access to the drive belt.
4. Remove both splice plates that are mounted on either side of the motor. Use a 5/32” Allen wrench
to remove the 12 screws holding the splice plates. There are enough remaining screws to keep
rewind and applicator plates in place.
5. Loosen the four (4) screws on the side of the motor mounting plate using a 5/32” Allen wrench.
6. Push the motor mount assembly upward and re-tighten mounting screws.
7. Disengage nip roller and turn the drive roller. Make sure there is no severe catching as you turn
the roller.
8. Check belt tension. With light finger pressure on one side of the belt, adjust the tension so that the
belt deflects approximately 1/16” to 1/8”.
NOTE: Do not over tighten the belts. This may result in shortened motor life. If belts are too loose,
label stop may become erratic.
9. Replace the two splice plates.
10. Replace the air lines interconnecting the two sides of the applicator.
11. Replace the stainless cover and tighten the mounting screws.
12. Re-connect the AC power and air.
76