Service manual

_______________
CROSSOVER SETUP
CROSSOVER MONITORING
If the applicator is a secondary labeler, the crossover sub-menu will have a MONITOR SECONDARY
SETUP selection. This menu is provided to aid the operator in setting up the crossover network and is
particularly helpful if the secondary applicator is not labeling or is double labeling products. If this is
selected, a screen will show the status of the following items:
PRODUCTS BETWEEN HEADS: xx
PRODUCTS BEFORE LABEL: xx
SECONDARY INHIBIT INPUT: ON/OFF
The products between heads value indicates how many products are between the primary and secondary
applicators while the products before label value indicates how many of these products are already labeled.
The secondary inhibit status indicates whether the secondary labeler is enabled or not. If the inhibit input
is ON, the secondary applicator is not labeling. If the inhibit input is OFF, the secondary applicator is
labeling.
CROSSOVER PRECAUTIONS !
The crossover option insures that all products on a conveyor system are labeled by providing a redundant
system that will be activated if the primary applicator encounters an alarm. The following precautions
should be observed for reliable operation of the crossover network:
Both the primary and secondary applicators should be of the same type and have identical setups
including the label sensors which should be set to detect the same edge on the label.
Make sure the product detect sensors are properly configured so that multiple product detect
signals are not sent to the applicators. Multiple product detects will cause the crossover counters
to be wrong. When setting-up the system, it is a good idea to monitor the “Products Between
Heads” counter. When there are no products between the heads, this counter should be zero. If at
any instance of time the “Products Between Heads” counter doesn’t match what the operator
physically counts between the applicators, multiple product detects are being generated.
Make sure that both applicators are brought online before the primary applicator labels the first
product. Going online synchronizes the two applicators.
Do not take products off the conveyor system that are between the heads. This will cause the
crossover counters to be wrong.
When the primary applicator enters into an alarm condition, allow the secondary applicator to
begin labeling before bringing the primary applicator back online. Failure to observe this
precaution will result in double labeled or skipped products. Generally this will not be a problem
since it will take some time to correct the problem, press alarm reset, and bring the primary
applicator back online.
If either applicator is powered down, the other applicator will not receive product detect signals.
Disconnect the crossover cable between the applicators when performing service on one of the
applicators or when crossover is not being used.
47