Service manual

_____________________________
PRODUCT SETUP PROCEDURE
PRODUCT SETUP
1. Make sure the power is on and the applicator is offline.
2. Press “PRODUCT SETUP” on the display.
3. The product setup screen will show the status of the detector lockout function, whether the
encoder is on or off and its speed, the label counter value, and whether the product sensor is
detecting a product or not. Note: If you are set for light operate “LO” on the product sensor,
the product detect indicator will say “YES” when there is no product in between the sensor
and reflector.
4. There are three submenus associated with this screen:
DET LOCKOUT ON/OFF: The product detector lockout function is used if more than one
product detect signal is generated per product. When the first product detect signal is received, a
timer is started and all other product detect signals are ignored until this time expires. Warning:
this works only when the product sensor is set for dark operate “DO”.
a) To add detector lockout, select “DET LOCKOUT” and enter a value between .001-20 seconds.
b) A valid detector lockout entry will send you back to the product setup menu.
ENCODER SETUP: SEE THE ENCODER SETUP SECTION OF THIS MANUAL
LABEL COUNTER: The label counter is a user resettable counter that keeps track of the number
of labels applied by the applicator since it was last reset. With this feature, the number of labels
per hour, per shift, etc. may be monitored.
a) To reset the label counter, select “LABEL COUNTER” from the product setup menu.
b) Select “YES” to reset the counter or “NO” to go back to the product setup menu.
LABEL PLACEMENT (also known as Label Delay)
When a product detect signal is received, the product must travel the “label placement” time or distance
before the applicator will dispense a label. Label placement gives you the ability to adjust where the label
is applied on the product.
More label placement = label moves back on the product
Less label placement = label moves forward on the product
1. To change label placement, press “LABEL PLACEMENT” on the display. Enter a value between
.001 and 20 seconds and press “ENTER”.
2. A valid label placement value will send you back to the main menu.
39