LABELER TYPE SETUP PROCEDURE
TAMP SLIDE
The tamp slide is used to move the label pad and manifold toward the product. The speed at which it
travels is a function of air pressure and airflow. The valve and regulator for the tamp assembly is part of
the valve bank mounted to the side of the applicator. Typically, the air pressure should be set between 40
and 50 PSI but it may be changed as necessary. Two adjustment knobs are provided on the air cylinder to
adjust the tamp extend and retract times. Turning the knobs clockwise will slow the movement of the
cylinder. Turning the knobs counter-clockwise will speed up the cylinder.
The tamp extend and retract times must be setup by the operator since they are dependent on the setting of
the adjustment knobs. Both timers are in the “LABEL SETUP” section of the display.
EXTEND TIME: 1. The tamp extend time is the time necessary to fully extend the tamp slide
assembly. After the tamp extend time expires, an air blast forces the label off of
the label pad onto the product. In order to keep cycle times to a minimum, set the
extend time so that the air blast occurs when the slide reaches the fully extended
position.
2. To change the extend time press “LABEL SETUP” on the display. Pick “TAMP
EXTEND” and enter a value between .001-5 seconds.
3. A valid tamp extend entry will send you back to the label setup menu.
4. Press “HOME” to return to the main menu.
RETRACT TIME: 1. The tamp retract time is the time necessary to fully retract the tamp slide assembly.
At the end of the “tamp retract” time a label will be fed out onto the pad. Too
small of a value will cause a label to feed out before the label pad is in the home
position. Too high of a value will cause long cycle times.
2. To change the retract time, press “LABEL SETUP” on the display. Pick “TAMP
RETRACT” and enter a value between .001-5 seconds.
3. A valid tamp retract entry will send you back to the label setup menu.
4. Press “HOME” to return to the main menu.
NOTE: If tamp switches are used, it is only necessary to set both tamp extend & retract times to a
value higher than the time required. The tamp switches will override any excess time.