LABELER TYPE SETUP PROCEDURE
TAMP AIR ASSIST
The air assist tube blows a stream of air onto the label to force it up against the tamp pad during the label
feed. The air assist starts to blow when the web starts to move and stops when the label is on the pad. The
extended air assist time allows the air assist to blow after the label feed to help stabilize the label.
1. Adjust the air assist tube so it’s blowing in the center of label. Ensure that the label feeds out
against the label pad.
2. The regulator for the air assist is on the valve bank and should be set between 10 and 15 PSI.
This is a typical setting but it may be changed as needed.
3. If a longer air assist is needed to help position the label, press “LABEL SETUP” on the display.
Pick “EXTENDED AIR ASSIST” and enter a value between .001-1 second.
4. A valid air assist entry will send you back to the label setup menu.
5. Press “HOME” to return to the main menu.
TAMP AIR BLAST
The air blast transfers the label from the label pad to the product and is a function of time and air pressure.
1. The regulator for the air blast is on the valve bank and should be set between 40-50 PSI. This is
the typical setting but it may be changed if needed.
2. To change the air blast time, press “LABEL SETUP” on the display. Pick “AIR BLAST” and
enter a value between .010-1 second.
3. A valid air blast entry will send you back to the label setup menu.
4. Press “HOME” to return to the main menu.