Service manual
___________________________________
LABELER TYPE SETUP PROCEDURE
TAMP LABEL STOP
1. With the applicator online, jog a couple of labels.
2. Label stop position should be 1/32” from the peel edge tip.
3. If needed change the label stop value. (Refer to label stop setup in the general job setup)
TAMP VACUUM
The tamp vacuum is generated by a vacuum venturi located on the applicator. This vacuum is used to hold
the label on the label pad until the air blast releases it. Too much or too little vacuum can affect label
placement on the pad. The amount of vacuum may be changed by adjusting the air pressure to the vacuum
regulator feeding the venturi. A setting of 30-40 PSI is typical but it may be changed as needed.
WARNING: It is important to match label size with the label pad size so that no holes are
uncovered when the label is on the pad. This may result in losing vacuum.
34