Service manual
___________________________________
LABELER TYPE SETUP PROCEDURE
AIR BLOW AIR ASSIST
The air assist tube blows a stream of air onto the label to force it up against the blow box grid during the
label feed. The air assist starts to blow when the web starts to move and stops when the label is on the
grid. The extended air assist time allows the air assist to blow after the label feed to help stabilize the label.
1. Adjust the air assist tube so it’s blowing into the center of the label. Ensure that the label feeds
out against the grid properly.
2. The regulator for the air assist is on the valve bank and should be set between 10 and 15 PSI.
This is a typical setting but it may be changed as needed.
3. If a longer air assist is needed to help position the label, press “LABEL SETUP” on the display.
Pick “EXTENDED AIR ASSIST” and enter a value between .001-1 second.
4. A valid air assist entry will send you back to the label setup menu.
5. Press “HOME” to return to the main menu.
AIR BLOW AIR BLAST
The air blast transfers the label from the grid to the product and is a function of time and air pressure. The
air blast pressure is regulated by the filter/regulator assembly located upstream of the valve.
1. The regulator for the air blast should be set between 40-50 PSI. This is the typical setting but it
may be changed as needed.
2. If the air blast time needs changed, press “LABEL SETUP” on the display. Pick “AIR BLAST”
and enter a value between .010-1 second.
3. A valid air blast entry will send you back to the label setup menu.
4. Press “HOME” to return to the main menu.
32