Service manual
___________________________________
LABELER TYPE SETUP PROCEDURE
ENTERING LABEL PROFILING VALUES
1. Press “LABEL SETUP” then select “LABEL PROFILING”.
2. The label profiling menu shows the following three items:
Profile Rise Area
Profile Flat Area
Web Ratio
3. Press “1) PROFILE RISE AREA”. This is the distance the label travels before changing to the
mid-product labeling speed. Enter a value between 0.5 and 20. A valid entry will send you back
to the label profiling menu.
4. Press “2) PROFILE FLAT AREA”. This is the distance the label travels while at the mid-
product labeling speed. Enter a value between .001 and 20.
A valid entry will send you back to
the label profiling menu.
5. Press “3) WEB RATIO”. The web ratio is a multiplier applied to the web speed value to either
slow or speed-up the applicator during the profile flat area. This number will vary depending on
product shape and is usually determined by trial and error. Enter a value between .5 and 1.5.
A
valid entry will send you back to the label profiling menu.
NOTE: Label profiling is disabled when using the multi –label option.
PROFILING SUMMARY
Condition Product Shape
WEB RATIO < 1.0 Convex
WEB RATIO = 1.0 Flat Surface
WEB RATIO > 1.0 Concave
Web
Ratio
Setting
Speed during
0” to rise
distance
Speed during
rise to flat distance
Speed during flat
to label length
distance
< 1.0 web speed (web speed) (web
ratio)
web speed
= 1.0 web speed web speed web speed
> 1.0 web speed (web speed) (web
ratio)
web speed
25