Service manual
_______________________________
GENERAL SETUP PROCEDURES
LABEL STOP
1. The label stop value is the distance from the label edge to the label sensor. Allowed values are
between 0.03” and (label length – 0.06”).
NOTE: After software version 360-2b.25 any value less than .06 comes with a warning that says the
label stop can move when the web speed changes.
2. Press the “LABEL STOP” key. Enter a new value and press “ENTER”. If the value is out-of-
range, the display will show an out-of-range message for 2 seconds and then switch back to the
label stop menu.
3. A valid label stop entry will send you back to the main menu.
4. With the applicator
online, press “JOG”. If the label stop is not where you want it, go back into
the “LABEL STOP” menu and enter a new value.
NOTE: This adjustment can be made while the machine is running.
LABEL FORMATS
This option will let the operator view, save, load or delete up to 10 label setups. If a certain size label is
used over and over, you can save the label format and reload it at a later date. Parameters that are saved
are:
APPLICATOR TYPE ENCODER ON/OFF EXTENDED AIR ASSIST
LABEL LENGTH RATE COMPENSATION ACCELERATION
LABEL STOP TAMP EXTEND TIME DECELERATION
LABEL PLACEMENT TAMP RETRACT TIME LABEL ADVANCE TIME
WEB SPEED AIR BLAST TIME
Press the “LABEL FORMAT” key and enter “1800” for the password. The display will show the
following options:
1) VIEW LABEL FORMAT
2) LOAD LABEL FORMAT
3) SAVE LABEL FORMAT
4) DELETE LABEL FORMAT
Warning: The applicator must be offline to enter this menu!
View Format
This option will allow the operator to view the individual format parameters. Pick “1” at the label
format menu and select the format number you want to see. Pressing “ENTER” will take you
back to the label setup menu
21