Service manual
_______________________________
GENERAL SETUP PROCEDURES
LABEL LENGTH SETUP
1. Measure the distance from the leading edge of one label to the leading edge of the next. This will
be the “label length” value.
2. From the LABEL SETUP menu press “3” to adjust the “LABEL LENGTH” value.
3. Enter the length and press “ENTER”. If the value is less than 0.375” or more than 20”, the
display will show an out-of-range message for 2 seconds then switch back to the label length
menu. If the value shown is correct, pressing “ENTER” will take you back to the LABEL SETUP
menu.
4. If the label length value was changed in step 3, the applicator will dispense a label and advance to
the “LABEL STOP” menu. The operator may accept or modify the current label stop value as
needed and return to the LABEL SETUP menu by pressing “ENTER”.
5. Press “HOME” to go to the main menu.
NOTE: It’s important to set the label length to exactly what it is (don’t guess). If there is a missing
label on the liner, the web will feed the label length distance. This is important because of
the label sensor’s position relative to the peel edge.
After 3
*
missing labels in a row, a “no labels found” message will appear on the display. If a light
stack is connected to the applicator, it will flash at a steady rate. Correct the problem and press
“ALARM RESET” to clear the alarm.
*
After software version 360-2b.25, the number of
missing labels before a “no labels found” alarm is user adjustable in the SPECIAL
OPTIONS menu.
20