Service manual

_______________________________
GENERAL SETUP PROCEDURES
message is displayed indicating that the label stop may need adjusting. The operator may
override the controller’s value using the “LABEL STOP” menu.
MANUAL SETUP
The manual setup function is provided for those instances where auto setup does not work. The following
steps summarize the manual setup sequence:
1. With the applicator
offline, select “2” from the LABEL SETUP menu.
2. The display will show the two edge detection modes discussed in the paragraph above. Select “1”
for label LEADING EDGE or “2” for label TRAILING EDGE detection. Pressing “ENTER” at
this point will bypass the following steps and take you back to the “LABEL SETUP” menu.
3. If LEADING EDGE DETECT was selected, the applicator will instruct the operator to place the
label and liner under the sensor and press “LABEL SETUP” to continue.
If TRAILING EDGE DETECT was selected, the applicator will instruct the operator to place the
liner only under the sensor and press “LABEL SETUP” to continue.
The sensor measures the label sensitivity at this position and uses this value for the “ON”
condition.
4. If LEADING EDGE DETECT was selected, the applicator will instruct the operator to place the
liner only under the sensor and press “LABEL SETUP” to continue.
If TRAILING EDGE DETECT was selected, the applicator will instruct the operator to place the
label and liner under the sensor and press “LABEL SETUP” to continue.
The sensor measures the label sensitivity at this position and uses this value for the “OFF”
condition.
5. The display will show whether the sensor is looking at the gap or the label in the current position.
If the web is manually adjusted by turning the hand wheel, the display status will change as the
web moves past the label sensor. Pressing “ENTER” will take you to the LABEL LENGTH
menu.
6. The display will show the current label length setting. If it is incorrect, enter a new label length.
If the value shown is correct, pressing “ENTER” will take you back to the LABEL SETUP menu.
For additional help, see the LABEL LENGTH explanation shown below.
7. If the label length value was changed in step 6, the applicator will dispense a label and advance to
the “LABEL STOP” menu. The operator may accept or modify the current label stop value as
needed and return to the LABEL SETUP menu by pressing “ENTER”. For additional help, see
the LABEL STOP explanation shown below.
19