Service manual
_______________
DISPLAY PANEL
NOTE: If you press the applicator options key, the first screen shows all of the available options and
which ones are currently active. Selecting a particular option for the first time requires a
password. The password is 1800. Subsequent selections do not require a password as long
as you remain within an option menu. Going back to the home screen will disable the last
password entry.
LABEL PLACEMENT:
The label placement key lets you enter a label placement value. Label placement is the time or distance
from the product detect sensor to where the label is dispensed onto the product. If the value you’ve entered
is out-of-range, a message will let you know so that you can re-enter a different value. The allowed values
depend on whether or not the encoder option is on or not. In either case, the appropriate limits are shown
on the last line of the label placement display screen. The label placement value may be changed while the
applicator is running.
PRODUCT SETUP:
The product setup key provides access to the detector lockout and encoder setup submenus. Also, the
current status of the product detect sensor, web speed (if equipped with an encoder), and label counter
values are displayed. The user may reset the label counter by selecting that option from the display.
DETECTOR LOCKOUT: The detector lockout function is used when more than one product detect
signal is generated per product. The timer starts at the beginning of a labeling sequence and the applicator
will ignore product detect signals until this timer has timed out. Therefore, if you set this timer to a value
equal to the time it takes the product to pass by the labeler, it will only see the first product detect signal.
Allowed values are between .001 - 20 seconds.
ENCODER SETUP: Please refer to the ENCODER SETUP section of this manual.
NOTE: This area is password protected. The password is 1800. Going back to the home screen will
disable the last password entry.
12